Aerovox-Condenser-&-Resistor-Catalog-1929-1930.pdf

(2410 KB) Pobierz
CONDENSER and
RESISTOR MANUAL
and CATALOGUE 1929-1930
A Helpful Manual on the
Proper Use of Condensers and
Resistors
in
Radio Receivers
Detailed Specifications of
and Power Supply Units with
Condensers and Resistors
AEROVO X
AEROVOX WIRELESS CORPORATION
Cable Address
Radiwac, New York
70-82 WASHINGTON ST.
BROOKLYN, N. Y.
Code:
Bentley's
Sales Offices
94 Portland St.
Boston, Mass.
821 Dayton Savings and Trust Bldg.
Dayton, 0.
1602 Arcade Bldg.
St. Louis, Mo.
324 N. San Pedro St.
Los Angeles, Cal.
607 Kerr Bldg.
Detroit, Mich.
11 S. Desplaines St.
Chicago, Ill.
3815 Clairmont Ave.
Birmingham, Ala.
1913 Pacific Ave.
Dallas, Tex.
1427 L. C. Smith Bldg.
Seattle, Wash.
208 W. King St.
Toronto, Ont., Canada
430 -4th St., N. E.
Washington, D. C.
' f.
CONDENSER and
RESISTOR MANUAL
and CATALOGUE 1929.1930
A Helpful Manual on the
Proper Use of Condensers and
Resistors in Radio Receivers and
Power Supply Units with Detailed
Specifications
of AEROVOX
Condensers and Resistors
Published in the Interests of Better Radio by
AEROVOX WIRELESS CORPORATION
70-82 WASHINGTON ST.
Cable Address
Radiwac, New York
Code:
Bentley's
BROOKLYN, N. Y.
AEROVOX PRODUCTS ARE "BUILT BETTER"
NDENSERS AND RESIST.,
BUILT BETTER
GENERAL FEATURES AND INSULATION SPECIFICATIONS OF
ALL AEROVOX PAPER DIELECTRIC CONDENSERS
Aerovox paper condensers can
On manufacturer's order,
Capacity Tolerance
be made to
any standard
specifications.
Special Capacities
tolerance in accordance with
Winding Characteristics
All standard Aerovox paper
condensers listed
in
this
catalog
are non - inductively
wound.
Inductively wound
The insulation resistance of
all Aerovox condensers is in
excess of R. M. A. and N. E.
M. A. standard requirements.
Insulation Resistance
condensers can be furnished
Smaller, larger or interme-
capacity or voltage rating, on
diate sizes, as well as combi-
special order.
nations of various units into
Safety Factor
blocks or special units can be
made to manufacturers'
All Aerovox paper conden-
specifications in standard or
sers are scientifically designed,
special cans or containers.
built
and rated
to
operate
safely at their rated working
Impregnation
voltages. The safety factor is
All Aerovox paper conden-
sers
are impregnated scien-
in excess of that required to
tifically by means of a special
withstand both R. M. A. and
process improved by the Aero-
to manufacturers in any
All dielectric material used
in Aerovox paper condensers
of all capacities and working
voltages is pure, 100 per cent
alkali, bleaching material and
impurities.
Dielectric Material
linen paper, free from acid,
N. E. M. A.
retest
ments
of
vox organization. The special
impregnating compound used
in Aerovox condensers has a
high melting
point
of
195
degrees
Fahrenheit, which
protects the condenser against
the heat developed in modern
voltages for 15 seconds after
which the condenser is to be
twice
require-
the
rated
Dependability
Aerovox condensers are be-
ing used in large quantities by
receiver
manufacturers who
realize the importance of send-
ing out receivers which they
can be sure will not be re-
immediately
ohms or more.
discharged
through
a
resistance
of
50
amplifier and power supply
units.
Standard Packages
They have been selected by the
largest and best known manu-
facturers only after exhaustive,
turned for service and repairs
due to condenser breakdowns.
competitive tests have proved
conclusively
the
ability
of
All Aerovox paper conden-
The average melting point
sers listed in this catalog are
Aerovox condensers to per-
of the paraffins still used in
packed one in a box. A stand-
form
safely and
efficiently
many condensers is approxi-
ard package contains ten
under
all conditions of
mately 130 degrees Fahrenheit.
boxes.
operation.
How To Use
INSULATION SPECIFICATIONS
Insul. Spec.
Of Aerovox Pa er Dielectric Condensers
A Word About
Voltage
Ratings
any given volt-
age series have
All capacities of
Chart
Maximum
D. C.
Working
Voltage
200
300
400
400
500
Maximum
A. C.
Working
Voltage
D. C,
Retest
Voltage
(15 sec.)
400
600
Total
Number
of
Papers
4
6
No. of
Papers
Between
Plates
2
-Thickness
of Each
Paper in
Inches
.0005
Total
Thickness
of Insul.
Bet. Plates
.001
tion specifica-
tions. Run down
the first column
at the left of the
the same insula-
E125
200 -Volt Series-Types 200-S, 202, 207, 250, 260, 261, 270
AllAerovox
Paper Dielectric
Condensers a r e
300 -Volt Series-Types 300-S, 302,
175
307,
3
350, 360, 361
.0004
.0012
.0015
.002
400 -Volt Series-Types 400-S, 402, 407, 450, 460, 461
1- 250
800
6
.0005
I
3
1
conservatively
rated for safety.
Because of the
comparative lack
of
standardiza-
voltage rating is
found. All char-
acteristics of the
chart till the
desired D.C.
250
300
350
i
r
400 -Volt Series-Type 470
800
----2
-F7-01111.
500 -Volt Series-Type 502
1000 -I
8
{
----1664-- 1 -0
600 -Volt Series-Types 602, 650, 670
1200
-01 -6- condenser manu-
.002
tion of some
600
800
1000
1000
I
series of con-
densers listed on
the
line
above
I-- 8
I
I
4
I
.0005
.0005
I
voltage
ratings,
facturers on
800 -Volt Series-Type 802
I
440
I
1600
10
will be found to
1V----1-21:TOU112F---6170-1703--1--
600
800
I
1000 -Volt Series-Types 1002, 1003, 1051
1000-
2000
I5
1
I
I
.0025
.003
.003
condensers
pared on the
basis of their
insulation speci-
fications for any
should be com-
the right of the
D.C. voltage rat
ing.
Two dif
olt Series-Type 1070
1
6
3-1-700T-
3-1--:.01:107
-1--
1500 -Volt Series-Type 1503
1500
-20-0-0-
ferent types of
3000
12
.0045
.006
given capacity
insulation are
used in the 400
and 1 0 0 0 volt
classes, as indi-
cated.
2500
and price. Aero-
-1-1-1150---4818r--E-12- 1----6-1-7001,
2500 -Volt Series-Type 2503
1
2000 -Volt Series-Type 2003
vox makes no
I
secret of the
condensers.
..
.007
I
For detai ed specifications and prices of the items listed
. ove consult the detailed
descriptions of those units in the other pages of this catalog.
.
.
insulation speci-
fications of its
APPROVED AND USED BY THE BEST-KNOWN SET MANUFACTURERS
Page 3
Zgłoś jeśli naruszono regulamin