Astraada HMI CFG.pdf

(11078 KB) Pobierz
CHAPTER 1
INTRODUCTION
1.1.
1.2.
1.3.
Getting Started.............................................................................................. 1
Documentation Conventions ......................................................................................... 1
1.1.1.
Project Development Steps .......................................................................... 2
Installing Astraada HMI CFG .................................................................... 3
System Requirements .................................................................................................... 3
Software Installation Astraada HMI CFG ..................................................................... 3
1.3.1.
1.3.2.
1.4.
Using Astraada HMI CFG........................................................................... 5
Main Menus ................................................................................................................... 5
Toolbars ....................................................................................................................... 17
Project Manager........................................................................................................... 26
Screen Manager ........................................................................................................... 34
Popup Menus ............................................................................................................... 36
1.4.1.
1.4.2.
1.4.3.
1.4.4.
1.4.5.
-i-
4
1
Astraada HMI CFG Operation Manual
1.1. Getting Started
Welcome to Astraada HMI CFG
Thank you for purchasing Astraada HMI CFG. This manual describes Astraada HMI CFG operation procedures and details
about each feature.
Notes
1) All programs and documentation included with Astraada HMI CFG ("this product") are the copyright of ASTOR Sp. z
o.o., and are licensed to the user under the Software License Agreement. Any violation of the conditions described in
the Software License Agreement is prohibited under Taiwanese and international laws.
2) ASTOR Sp. z o.o. makes every attempt to provide the user with functionality and usability of the Product and accuracy
of its documentation. However, if you should find any errors or omissions in this manual, please contact ASTOR Sp. z
o.o..
3) Regardless of the above provisions, ASTOR Sp. z o.o. shall not be held responsible for any damages or third party
claims resulting from the use of this product.
4) Difference may occur between the descriptions found in this manual and the actual functioning of this product. For the
latest information, please refer to the provided data files (i.e. readme.txt files, etc) or other ASTOR Sp. z o.o.
documentation.
5) Information recorded in or displayed by this product may include content related to intangible assets or intellectual
properties owned by ASTOR Sp. z o.o. or by a third-party. However, this does not imply that ASTOR Sp. z o.o. grants
the user or other third-parties any license or permits to use such assets or properties.
Precautions
1) Do not use the touch panel switch as an emergency stop switch. For safety reasons, it is required that all industrial
machinery and systems must be equipped with a mechanical, manually-operated emergency stop switch.
2) Do not use the touch panel switch that could result in human injury or equipment damage. Failure with the touch panel,
the processing unit, and the cables that makes the output stuck at ON or OFF could result in a serious accident.
1.1.1. Documentation Conventions
Product-related Abbreviations and Terminology
This manual uses the following terminology.
Terminology
Description
Controller
Application
Target Panel
Indicates controller, such as programmable logic controllers (PLCs), motion controllers, thermal
controllers, inverters, and so on.
The screen application created with the Astraada HMI CFG on the PC.
The HMI (Human-Machine Interface) unit or the computer that runs PanelExpress where the screen
application is downloaded to and displayed.
This manual uses the following abbreviations.
Abbreviations Corresponding Target Panel
PM
PE
LSK
TSK
WKT
All PanelMaster Series
PanelExpress
PL037-LSK, PV037-LSK, PV037V-LSK,
PL057-LSK, PV057-LSK, PV057V-LSK
PL057-TSK, PV057-TSK, PV057V-TSK
PL070-WKT, PV070-WKT
1-1
CHAPTER 1
INTRODUCTION
Astraada HMI CFG Operation Manual
1
1.2. Project Development Steps
Install and run
Astraada HMI CFG
Create a project
Set up project
protection
Global Settings
Languages
Font Templates
Picture Database
Sound Database
Text Database
Global Tags
Global macros
Create and set up
panel applications
Create and set
up links
Create local tags
Application setup
Command block
Status words
Clock
Passwords
Create and set
up screens
Alarm blocks
Recipe blocks
Data loggers
Design the screens
Operation logger
Local macros
Compile current
panel application
Simulate current
panel application
Download current
panel application
Run
1-2
CHAPTER 1 INTRODUCTION
4
1
Astraada HMI CFG Operation Manual
1.3. Installing Astraada HMI CFG
1.3.1. System Requirements
The following hardware / software is required to use Astraada HMI CFG.
Free hard disk space
Astraada HMI CFG, once installed, takes around 170 MB of hard disk space. The installation procedure (only at installation
time) requires twice as much (i.e. 340 MB).
RAM Working Memory
The memory requirements are as required by the OS. However minimum of 512MB RAM is recommended for decent
performance when user is having large projects with high color bitmaps.
Minimum OS requirements :
Windows 2000
SP4
Windows XP
SP2 (for all flavors of XP such as Home, Media Center, Tablet PC)
Windows Server 2003
Windows Vista
1.3.2. Software Installation Astraada HMI CFG
Installing Astraada HMI CFG
To install Astraada HMI CFG, you may do the followings:
1. Close all other programs.
2. Select and click setup.exe in the CD or Astraada HMI CFG installation folder.
3. Follow the on screen prompts.
4. The default location for the Astraada HMI CFG software is "c:\Program Files\Astraada HMI CFG. If you prefer to
change the
software at a different location on your hard drive, you have that option.
The installation procedure will create a program group entitled "Astraada
HMI CFG"
within Windows . A Astraada HMI
CFG icon
will be added to your desktop. Astraada HMI CFG also appears on the Windows
start menu under
Start
>
All Programs
>
Astraada HMI CFG.
Technical Support
For the questions about the Astraada HMI CFG software, contact
ASTOR Sp. z o.o.
by sending an email to the following
address: astraada.hmi@astor.com.pl.
How to Report a Bug
The Astraada HMI CFG development team is proud to present a high quality program with minimal bugs. Despite their best
efforts, however, bugs do occasionally appear in the software. Should you notice a problem with the software that you think
may be a bug, please report it to Astraada HMI CFG. Please e-mail to astraada.hmi@astor.com.pl.
Please include as much information as possible, including a description of the irregularity, the type of PC and panel that
you have, any other software that was running when the problem occurred, and the sequence of steps that led to the
problem.
Astraada HMI CFG Software License
This is a legal agreement between you (either an individual or a single entity) and ASTOR Sp. z o.o. for the Astraada HMI
CFG SOFTWARE, which includes computer software and may include associated media, printed materials, and 'on-line'
electronic documentation.
1-3
CHAPTER 1
INTRODUCTION
Zgłoś jeśli naruszono regulamin