FOUNDATION FIELDBUS DIAGNOSTIC POWER CONDITIONER SYSTEM DPC-49-4RMB USER MANUAL.pdf

(828 KB) Pobierz
FOUNDATION™
FIELDBUS
DIAGNOSTIC
POWER
CONDITIONER
SYSTEM
DPC-49-4RMB
USER MANUAL
All brand and product names are trademarks or registered trade marks of the owner
concerned.
Edition 09/08
© Hans Turck GmbH, Mülheim an der Ruhr
All rights reserved, including those of the translation.
No part of this manual may be reproduced in any form (printed, photocopy, microfilm or any
other process) or processed, duplicated or distributed by means of electronic systems
without written permission of Hans Turck GmbH & Co. KG, Mülheim an der Ruhr.
Subject to alterations without notice.
0
About this manual
Description of symbols used..............................................................................................................0-2
Introduction.........................................................................................................................................0-2
1
Introduction
Characteristics ....................................................................................................................................1-2
Extended diagnostics .....................................................................................................................1-2
Simple diagnostics .........................................................................................................................1-4
System overview.................................................................................................................................1-4
Figure DPC-49-4RMB.....................................................................................................................1-5
2
Mounting and installation
System components...........................................................................................................................2-2
Dimensional drawing ......................................................................................................................2-2
Connections and components of the DPC-49-4RMB.......................................................................2-3
DPC-49-IPS1 - Electrically isolated power supply (Fieldbus power supply) ..................................2-3
Dummy modules for unused slots ..................................................................................................2-4
H1 connections to the host ............................................................................................................2-4
H1 connections into the field ..........................................................................................................2-5
Power supply ..................................................................................................................................2-5
Power supply concept ....................................................................................................................2-6
Shielding..............................................................................................................................................2-7
Earthing ...............................................................................................................................................2-8
LEDs of the DPC-49-IPS1 module .....................................................................................................2-8
D301164 0908 - FF Diagnostic Power Conditioner System
i
ii
D301164 0908 - FF Diagnostic Power Conditioner System
Warning!
Dangerous electrical voltage!
Before beginning installation work
Disconnect the device from the power supply
Protect against accidental restart
Verify isolation from the supply
Earth and short-circuit the supply
Cover or close off neighbouring units that are live.
The assembly instructions provided for the device are to be complied with.
Only suitably qualified personnel according to EN 50 110-1/-2 (VDE 0105 part 100) are
authorised to carry out work on this device/system.
When conducting installation work ensure that you are free of electrostatic charge before
touching the device.
The functional earth (FE) must be connected to the protective earth (PE) or the
equipotential bonding. The system installer is responsible for establishing this connection.
Connection and signal cables are to be installed so that any inductive or capacitive
interference does not impair the automation functions.
The installation of automation devices and their operating elements is to be carried out in
such a way as to prevent unintentional operation.
In order to prevent cable or wire breakage on the signal side generating undefined states
in the automation devices, appropriate safety measures are to be taken for the I/O
coupling on the hardware and software side.
Ensure a reliable isolation of the extra-low voltage for the 24 volt supply. Only those power
supply units that comply with IEC 60 364-4-41, i.e. HD 384.4.41 S2 (VDE 0100 part 410)
are to be deployed.
Fluctuations or deviations of the mains voltage from the nominal value should not exceed
the tolerance limits specified in the technical data, otherwise malfunctions and dangerous
states may occur.
Emergency stop devices complying with IEC/EN 60 204-1 must remain effective in all
operating modes of the automation installation. Releasing the emergency stop devices
must not cause a restart.
Devices for mounting in housings or cabinets, desktop or portable units, are only to be
operated and controlled with the housing closed.
Measures are to be taken to ensure the correct restarting of a program following
interruption due to a voltage drop or failure. Dangerous operating conditions, even short
term, should not occur as a result. If required an emergency stop should be carried out.
External measures are to be implemented at those locations where faults in the automation
installation could lead to injury to persons or damage to property. These measures must
guarantee safe operating conditions even in the event of a fault or malfunction (e.g. by
means of independent limit switches or mechanical locking devices etc.).
The electrical installation must be carried out in accordance with the relevant regulations
(e.g. in respect of the cable cross sections, uses and protective earth connections).
All work involving transport, installation, commissioning and maintenance is to be carried
out exclusively by qualified personnel. (in accordance with IEC 60 364 i.e. HD 384 or DIN
VDE 0100 and national accident prevention regulations).
All covers and doors must be kept closed during operation.
D301164 0908 - FF Diagnostic Power Conditioner System
iii
Zgłoś jeśli naruszono regulamin